Summary for Test 2020-07-02-7-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 214601
DEA: 041J5694
EFIS: 0419000313
DIST-CO-RTE-PM04-SM-101-0.0/21.8
Award Date12/03/2019
Closeout Date09/28/2022
Work DescriptionSan Mateo US 101 Express Lanes North
Location DescriptionNot set
QA Service Level1 (Verified on 04/08/2022)

Sample Information

Sample Taken Date07/02/2020 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/09/2020
Sample typeQuality Assurance A brief description of the sample A325 Bolt Assembly
The quantity of what the sample constitutes127 From where was the sample collectedFabricator
First name of sampler or witnessed byStacey Last name of sampler or witnessed byDavis
Title of samplerQAI Telephone number of sampler562-480-6984
Laboratory sample identification Linked DIME Sample ID2020-07-02-8 & 9
The fabricator/manufacturer/facility nameStructural and Steel Products Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB362-003-20 Structure unique identifier
Structure nameHOV Rte 101

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)062220A
Heat Number(s)C170811 Nut Mfg. Lot Number(s)27724-75070238
Washer Mfg. Lot Number(s)5737 Bolt SpecificationASTM A325
Bolt Length(s)4" Nut SpecificationA563
Washer SpecificationF436 FinishHDG
Diameter/Size1-1/2"-6 Bolt Mfg. Lot Number125570
Rocap Test Requirement(s)240 degrees Lubricant Requirements(s)yes on nuts

Test Details

DIME Sample ID: 2020-07-02-7
DIME Test ID: 2020-07-02-7-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-07-15

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 07/14/2020
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1127724-75070238230103Nut Prooffsaylor

General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 7/15/2020