Test 2020-06-12-22-2 (CTM 521-June 2012) Summary

Project Information
Project IdentifiersProject ID: 214756
DEA: 050N7AU4
EFIS: 0520000030
DIST-CO-RTE-PM05-SB-101-1.4/4.8
Work DescriptionSegment 4A - Carpinteria: Construct HOV lanes and rehabilitation. Source inspection of sign structure trusses, lighting structures, epoxy coated rebar, precast box culverts, precast RCP.
Location DescriptionCARPINTERIA FROM 0.2 MILE SOUTH OF BAILARD AVENUE OVERCROSSING TO 0.7 MILE SOUTH OF SOUTH PADARO LANE
Sample Information
Sample Taken Date6/12/2020 Sample Unique Key22
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/13/2020
Sample typeQuality Control A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes92 cy From where was the sample collectedJob Site
First name of sampler or witnessed byZac Last name of sampler or witnessed byFlores
Title of samplerQC Technician Laboratory sample identificationC061220-404, 405, 406
The fabricator/manufacturer/facility nameHanson - Goleta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameFranklin and Santa Monica
Material Information
Material TypeConcrete The concrete mix design number725A1MOP
The truck number from where the sample was collected514D The batch plant ticket number from where the sample was collected35252
Concrete batch plantHanson Aggregates The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedPoint of Placement Where the material sample would have been placed if not sampledAbutment 1 and 2
From Lot No. Bag Lot No.
Test Details
DIME Sample ID: 2020-06-12-22
DIME Test ID: 2020-06-12-22-2
Testing Lab: Sequoia Consultant
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2020-07-29
Test Results

Number of specimens: 2
Input Type: Calculated
Tester's full name: Leo Santamaria
Date of test: 06/12/2020
Correction factor: 1
Cylinder Age: 28 days
Break Description of Cylinder 1 (if not 'cone'): 3
Break Description of Cylinder 2 (if not 'cone'): 3
Average Compressive Strength (to nearest 10):4940 lb/in^2
Compressive Strength of Cylinder 1:4920 lb/in^2
Compressive Strength of Cylinder 2:4950 lb/in^2
General comments (publicly viewable) (Max 1000 characters): Set 1 of 3

Test was verified on 07/29/2020