Test 2020-06-29-23-1 (AASHTO T27-14) Summary

Project Information
Project IdentifiersProject ID: 213603
DEA: 07301504
EFIS: 0714000020
DIST-CO-RTE-PM07-LA-1,10-R34.6/35.2,R2.1/18.4
Work DescriptionREPLACING CONCRETE AND AC PAVEMENT
Location DescriptionLOS ANGELES COUNTY IN SANTA MONICA AND LOS ANGELES ON ROUTE 1 FROM 0.1 MILE WEST OF MAIN STREET OVERCROSSING TO ROUTE 1/10 SEPARATION AND ON ROUTE 10 FROM ROUTE 1/10 SEPARATION TO ROUTE 5/10 SEPARATION AND AT ROUTE 10/110 SEPARATION
Sample Information
Sample Taken Date6/29/2020 Sample Unique Key23
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/2/2020
Sample typeVerification A brief description of the sample1/2" RMHA-G-SP 0.5% LAS
The quantity of what the sample constitutes4 Bags Of Coldfeed Aggregate From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Irwindale Last name of sampler or witnessed byQC
Title of sampler Laboratory sample identification0400G-20
The fabricator/manufacturer/facility nameFish Canyon - Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-19-0035
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant number326120A IRW LTR A detailed description of where the material sample was collectedConveyor Belt
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown JMF Verification ID
Test Details
DIME Sample ID: 2020-06-29-23
DIME Test ID: 2020-06-29-23-1
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-07-13
Test Results

What type of gradation is being tested?: Combined Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Input Type: Calculated
Tester's full name: Juan Le Roy, Satish jain
Date of test: 07/06/2020
Cumulative percent passing the 2 in. sieve:100 %
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:100 %
Cumulative percent passing the 1/2 in. sieve:97 %
Cumulative percent passing the 3/8 in. sieve:86 %
Cumulative percent passing the #4 sieve:44 %
Cumulative percent passing the #8 sieve:23 %
Cumulative percent passing the #16 sieve:16 %
Cumulative percent passing the #30 sieve:11 %
Cumulative percent passing the #50 sieve:8 %
Cumulative percent passing the #100 sieve:6 %
Cumulative percent passing the #200 sieve:4.5 %
General comments (publicly viewable) (Max 1000 characters): Combined Virgin Aggregate Gradation

Test was verified on 07/13/2020