Summary for Test 2020-06-10-32-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 214589
DEA: 020J1604
DIST-CO-RTE-PM02-PLU-284-0.0/8.3
Award Date02/11/2020
Closeout Date10/06/2020
Work DescriptionPLACE HMA (TYPE A), PRECOATED AGGREGATE (SEAL COAT), HMA (LEVELING).
Location DescriptionPLUMAS COUNTY NEAR CHILCOOT FROM ROUTE 70 TO 1 MILE NORTH OF LITTLE LAST CHANCE CREEK BRIDGE NUMBER 09-0072
QA Service Level1 (Verified on 01/22/2020)

Sample Information

Sample Taken Date06/10/2020 Sample Unique Key32
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/11/2020
Sample typeVerification A brief description of the sample3/8-inch Type A Untreated Virgin Aggregate
The quantity of what the sample constitutesJMF Verification From where was the sample collectedSource
First name of sampler or witnessed byCGI Last name of sampler or witnessed byCGI
Title of sampler Telephone number of sampler
Laboratory sample identificationD78468 20-05 Linked DIME Sample ID
The fabricator/manufacturer/facility nameWard Lake Pit Transportation Laboratory (TL) Number896983
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-18-0008::WARD LAKE PIT
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedLab-Batched from Sized Untreated Aggregate Stockpiles
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberJMF 20-05-S1a Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-06-10-32
DIME Test ID: 2020-06-10-32-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-07-10

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Ward Jenkins
Date of test: 07/06/2020
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 100 %
Cumulative percent passing the 3/8 in. sieve: 95.7 %
Cumulative percent passing the 1/4 in. sieve: 69.2 %
Cumulative percent passing the #4 sieve: 57.7 %
Cumulative percent passing the #8 sieve: 34.9 %
Cumulative percent passing the #16 sieve: 21.2 %
Cumulative percent passing the #30 sieve: 12.9 %
Cumulative percent passing the #50 sieve: 7.9 %
Cumulative percent passing the #100 sieve: 4.8 %
Cumulative percent passing the #200 sieve: 3.46 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/10/2020