Summary for Test 2020-06-18-20-7

Test performed: ASTM D4791-10

Project Information

Project IdentifiersProject ID: 214695
DEA: 120R8604
EFIS: 1219000048
DIST-CO-RTE-PM12-ORA-5-28.3/31.8
Award Date04/02/2020
Closeout Date01/04/2021
Work DescriptionCOLD PLANE AC PVMT AND PLACE RHMA.
Location DescriptionORANGE COUNTY IN TUSTIN AND SANTA ANA FROM TUSTIN RANCH ROAD UNDERCROSSING TO GRAND AVENUE UNDERCROSSING
QA Service Level1 (Verified on 12/10/2020)

Sample Information

Sample Taken Date06/18/2020 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/26/2020
Sample typeVerification A brief description of the sample3/4" RWMA-G-SP Aggregate
The quantity of what the sample constitutesPSU 4 bags Combined From where was the sample collectedManufacturer
First name of sampler or witnessed byV Last name of sampler or witnessed byPham
Title of sampler Telephone number of sampler
Laboratory sample identification0380G-20 Linked DIME Sample ID
The fabricator/manufacturer/facility nameR J Noble Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0035::EAGLE VALLEY QUARRY
The fabricator's/manufacturer's product name for the sample3/4 Inch RWMA-G-SP The fabricator/manufacturer designation for the sampleUnknown
The plant number49R003ARSPWEO A detailed description of where the material sample was collectedConveyor Belt
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-06-18-20
DIME Test ID: 2020-06-18-20-7
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2020-07-02

Test Results


Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles

Method: B
Determination: By Mass
Dimensional ratio used: 5:1
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 07/01/2020
Weighted percentage of particles (by mass) that were flat and elongated: 3 %
Weighted percentage of particles (by mass) that were not flat and elongated: 97 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/2/2020