Test 2020-05-20-37-3 (AASHTO T96-02r10) Summary

Project Information
Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
Sample Information
Sample Taken Date5/20/2020 Sample Unique Key37
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/21/2020
Sample typeAggregate Prequalification Program A brief description of the sample3/4" HMA
The quantity of what the sample constitutes4 Buckets From where was the sample collectedSource
First name of sampler or witnessed byPlant Last name of sampler or witnessed byTechnician
Title of sampler Laboratory sample identification20-0096
The fabricator/manufacturer/facility nameGraniterock - AR Wilson Quarry Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-35-0012
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown HMA Design ID
Test Details
DIME Sample ID: 2020-05-20-37
DIME Test ID: 2020-05-20-37-3
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2020-07-01
Test Results

Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 06/24/2020
Grading designation: C
Mass of sample (before test): 5002 grams
Mass of sample on No.12 sieve (after 100 revolutions): 4588 grams
Mass of sample on No.12 sieve (after 500 revolutions): 3263 grams
Percent loss after 100 revolutions:8 %
Percent loss after 500 revolutions:35 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 07/01/2020