Test 2020-06-26-4-1 (CTM 643-April 2020) Summary

Project Information
Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Sample Information
Sample Taken Date6/26/2020 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/26/2020
Sample typeQuality Assurance A brief description of the sampletest
The quantity of what the sample constitutes1 From where was the sample collectedFabricator
First name of sampler or witnessed bytest Last name of sampler or witnessed byest
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nametest Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedtest
Where the material sample would have been placed if not sampledUnknown
Test Details
DIME Sample ID: 2020-06-26-4
DIME Test ID: 2020-06-26-4-1
Testing Lab: CT HQ - Sacramento Office of Structural Materials Field Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-06-30
Test Results

The test method used?: Laboratory Resistivity Test for Water
Input Type: Measured
Tester's full name: David Phong
Date of test: 06/30/2020
Water resistance: 2 Ohms
Water sample temperature: 3 C
Soil box constant: 2
pH of water: 1.00
Water sample resistance corrected to 15.5: 1.38 Ohm-cm
Resistivity of water at 15.5:3 Ohm-cm
General comments (publicly viewable) (Max 250 characters):

Test was verified on 06/30/2020