Summary for Test 2020-06-26-4-1

Test performed: CTM 643-April 2020

Project Information

Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level (Verified on 04/05/2013)

Sample Information

Sample Taken Date06/26/2020 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/26/2020
Sample typeQuality Assurance A brief description of the sampletest
The quantity of what the sample constitutes1 From where was the sample collectedFabricator
First name of sampler or witnessed bytest Last name of sampler or witnessed byest
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nametest Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedtest
Where the material sample would have been placed if not sampledUnknown

Test Details

DIME Sample ID: 2020-06-26-4
DIME Test ID: 2020-06-26-4-1
Testing Lab: CT HQ - Sacramento Materials Management Branch Field Office
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-06-30

Test Results


The test method used?: Laboratory Resistivity Test for Water (pH and Resistivity)
Input Type: Measured
Tester's full name: David Phong
Date of test: 06/30/2020
Water resistance: 2 Ohms
Water sample temperature: 3 C
Soil box constant: 2
pH of water: 1.00
Water sample resistance corrected to 15.5: 1.38 Ohm-cm
Resistivity of water at 15.5: 3 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/30/2020