Summary for Test 2020-05-06-27-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 214377 DEA: 020J2204 EFIS: 0219000073 |
---|---|
DIST-CO-RTE-PM | 02-TRI-299-32.0/33.0, 32.0-33.0, 32/33, 32-33, 32.0 / 33.0 |
Award Date | 01/14/2019 |
Closeout Date | 12/23/2020 |
Work Description | Exc & stabilize rock slide or secure large rocks |
Location Description | Not set |
QA Service Level | 1 (Verified on 09/16/2019) |
Sample Information
Sample Taken Date | 05/06/2020 | Sample Unique Key | 27 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/06/2020 |
Sample type | Acceptance | A brief description of the sample | Combined RAP (1/2-inch) |
The quantity of what the sample constitutes | Up to Five Days Paving | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Dorell | Last name of sampler or witnessed by | Harper |
Title of sampler | Consultant | Telephone number of sampler | |
Laboratory sample identification | D78420B | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Northstate Asphalt, Redding, CA | Transportation Laboratory (TL) Number | 002555 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | Northstate Asphalt, Redding, CA |
---|---|---|---|
Aggregate Size | 1/2-inch | Aggregate Source | Unknown |
RAP Stockpile | Stockpile Size (tons) | Unknown | |
Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2020-05-06-27
DIME Test ID: 2020-05-06-27-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-06-25
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Ward Jenkins
Date of test: 05/07/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1587.6 g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 5.91 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/25/2020 ✔