Summary for Test 2020-05-12-22-11

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 214868
DEA: 074P4204
EFIS: 0717000231
DIST-CO-RTE-PM07---
Award DateNot set
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 06/30/2021)

Sample Information

Sample Taken Date05/12/2020 Sample Unique Key22
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/03/2020
Sample typeVerification A brief description of the sample3/8 WMA-A-SP R15 Aggregates and RAP
The quantity of what the sample constitutesJMF 8 Bags From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Sun Valley Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0289A-20 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Sun Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0017, 91-19-0019, 91-19-0021
The fabricator's/manufacturer's product name for the sample3/8 WMA-A-SP R15 The fabricator/manufacturer designation for the sampleUnknown
The plant number420816 SVA LTR A detailed description of where the material sample was collectedBelt Cut at Vulcan Sun Valley Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-05-12-22
DIME Test ID: 2020-05-12-22-11
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-06-24

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Satish Jain, David Valenzuela
Date of test: 06/24/2020
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 100 %
Cumulative percent passing the 3/8 in. sieve: 91 %
Cumulative percent passing the #4 sieve: 64 %
Cumulative percent passing the #8 sieve: 47 %
Cumulative percent passing the #16 sieve: 36 %
Cumulative percent passing the #30 sieve: 26 %
Cumulative percent passing the #50 sieve: 15 %
Cumulative percent passing the #100 sieve: 6 %
Cumulative percent passing the #200 sieve: 2.9 %
General comments (publicly viewable) (Max 1000 characters): Combined Virgin aggregate

Test was verified on 6/24/2020