Summary for Test 2020-06-16-8-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 214543 DEA: 080K8404 EFIS: 0800020563 |
---|---|
DIST-CO-RTE-PM | 08-SBD-L5726- |
Award Date | 01/09/2020 |
Closeout Date | 04/28/2022 |
Work Description | MAINTENANCE STATION BUILDING WORK. |
Location Description | SAN BERNARDINO AT THE SAN BERNARDINO MAINTENANCE STATION AT 175 WEST CLUSTER STREET |
QA Service Level | 1 (Verified on 02/26/2020) |
Sample Information
Sample Taken Date | 06/16/2020 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/22/2020 |
Sample type | Quality Assurance | A brief description of the sample | F1554 Gr 36 anchor bolts |
The quantity of what the sample constitutes | 67 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Chris | Last name of sampler or witnessed by | Dsouza |
Title of sampler | QA Inspector | Telephone number of sampler | 646-942-3585 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Cordova Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L132-094-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 1202008878,3500007821 | Nut Mfg. Lot Number(s) | 434578A |
Washer Mfg. Lot Number(s) | Bolt Specification | F1554 Gr 36 anchor bolts | |
Bolt Length(s) | 30" | Nut Specification | A563 DH |
Washer Specification | NA | Finish | |
Diameter/Size | 7/8 | Bolt Mfg. Lot Number | 2005227A 2/3 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2020-06-16-8
DIME Test ID: 2020-06-16-8-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-07-02
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 06/24/2020
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 2 | 434378A | 73202 | Nut Proof | bewing |
General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 7/2/2020 ✔