Summary for Test 2020-05-27-10-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 213598
DEA: 051F75U4
EFIS: 0518000092
DIST-CO-RTE-PM05-MON-101-R36.9/47.7
Award Date01/16/2019
Closeout Date01/11/2024
Work DescriptionCRCP, SEISMIC RETROFIT, BRIDGE WIDENING AND MEDIAN BARRIER
Location DescriptionMONTEREY COUNTY IN AND NEAR KING CITY FROM 0.4 MILE SOUTH OF WILD HORSE ROAD OVERCROSSING TO TEAGUE AVENUE
QA Service Level1 (Verified on 10/11/2018)

Sample Information

Sample Taken Date05/27/2020 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/19/2020
Sample typeAcceptance A brief description of the sample7/8" x 3" F3125 A325 MG
The quantity of what the sample constitutes22 From where was the sample collectedSource
First name of sampler or witnessed byAaron Last name of sampler or witnessed byFranklin
Title of samplerMR Telephone number of sampler(858) 699-0513
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSt Louis Screw and Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)AAAM087300
Heat Number(s)10587830 Nut Mfg. Lot Number(s)N/A
Washer Mfg. Lot Number(s)N/A Bolt SpecificationF3125 A325
Bolt Length(s)3 Nut SpecificationN/A
Washer SpecificationN/A FinishMG
Diameter/Size7/8 x 3 Bolt Mfg. Lot NumberBM0723
Rocap Test Requirement(s)Yes Lubricant Requirements(s)Yes

Test Details

DIME Sample ID: 2020-05-27-10
DIME Test ID: 2020-05-27-10-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2020-06-22

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 06/19/2020
UTM: 450kip
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11BM07230.875064610287.410.00A325 Boltbewing

General comments (publicly viewable) (Max 1000 characters): A325 Bolt
Test Graph
Source: Bluehill Data Point File

Test was verified on 6/22/2020