Test 2020-06-02-20-5 (AASHTO T324-14) Summary

Project Information
Project IdentifiersProject ID: 213942
DEA: 051F7004
EFIS: 0514000055
DIST-CO-RTE-PM05-MON-101-73.1/87.3
Work DescriptionREPLACE CONCRETE PANEL AND RESURFACE HMA PAVEMENT.
Location DescriptionMONTEREY COUNTY NEAR CHUALAR FROM 0.5 MILE NORTH OF NORTH GONZALES OVERCROSSING TO EAST MARKET STREET UNDERCROSSING
Sample Information
Sample Taken Date6/2/2020 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/15/2020
Sample typeVerification A brief description of the sampleBoxes of RHMA-G
The quantity of what the sample constitutesOne JMF Renewal From where was the sample collectedManufacturer
First name of sampler or witnessed byWesley Last name of sampler or witnessed byRider
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameGraniterock Aromas Batch Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot numberUnknown
Sublot numberUnknown JMF Verification ID JMF3513-2020-145
Test Details
DIME Sample ID: 2020-06-02-20
DIME Test ID: 2020-06-02-20-5
Testing Lab: CT D05 - Field Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2020-06-18
Test Results

Input Type: Calculated
Tester's full name: E. Atkins
Date of test: 06/17/2020
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average:15000
Impression at specified number of passes average:6.21 mm
HMA Production:Field Plant Produced
Specified number of passes at 12.7 mm:15000
Specified number of passes at inflection point:no data
Type and Amount of Anti-Stripping Additive:0.75% Cecabase contains XL-9000 LAS
Compaction Method:SGC Cylindrical Specimen
Test Temperature:122 F
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A):15000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B):15000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A):7.08 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B):5.33 mm
Stripping Inflection Point (Wheel A):17550
Stripping Inflection Point (Wheel B):>25000
General comments (publicly viewable) (Max 250 characters):

Test was verified on 06/18/2020