Summary for Test 2020-06-12-2-1
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 212324 DEA: 033F5104 EFIS: 0313000020 |
---|---|
DIST-CO-RTE-PM | 03-YUB-20-R18.1/R20.1 |
Award Date | 10/31/2019 |
Closeout Date | 08/03/2023 |
Work Description | Construct bridge, realign curve & widen shoulders. |
Location Description | Construction on state highway in Yuba County near Smartsville from the Yuba River Bridge to 0.3 mile east of Smartsville Road. |
QA Service Level | 1 (Verified on 02/27/2020) |
Sample Information
Sample Taken Date | 06/12/2020 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/16/2020 |
Sample type | Quality Assurance | A brief description of the sample | 3/4" HDG Washer |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Paul | Last name of sampler or witnessed by | Farinha |
Title of sampler | ASSOC STEEL INSP | Telephone number of sampler | 9167987102 |
Laboratory sample identification | Linked DIME Sample ID | 2020-06-12-1 | |
The fabricator/manufacturer/facility name | Gerlinger | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | n/a | |
Washer Mfg. Lot Number(s) | 1118-002 | Bolt Specification | n/a |
Bolt Length(s) | Unknown | Nut Specification | n/a |
Washer Specification | ASTM F436 | Finish | Hot Dipped ASTM A153 / ASTM F2329 |
Diameter/Size | 3/4" | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2020-06-12-2
DIME Test ID: 2020-06-12-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2020-06-17
Test Results
Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 06/17/2020
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 1118-002
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: TSI F436
Size: .75 in
Bolt Length: no data
Measurement Average: 3.16 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/17/2020 ✔