Summary for Test 2020-06-15-9-2
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 212899 DEA: 051C6704 EFIS: 0512000194 |
---|---|
DIST-CO-RTE-PM | 05-SCR-17-0.2-0.5 |
Award Date | 02/08/2019 |
Closeout Date | 09/23/2022 |
Work Description | PASATIEMPO RETAINING WALL - |
Location Description | IN SANTA CRUZ FROM 0.5 MILE TO 0.3 MILES SOUTH OF PASATIEMPO OVERCROSSING |
QA Service Level | 1 (Verified on 04/01/2019) |
Sample Information
Sample Taken Date | 06/15/2020 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/15/2020 |
Sample type | Verification | A brief description of the sample | Lab Mix for CTM 368 |
The quantity of what the sample constitutes | Lab Mix | From where was the sample collected | Other |
First name of sampler or witnessed by | Danilo | Last name of sampler or witnessed by | Ramirez |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Made in D5 Lab | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | OGFC |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-06-15-9
DIME Test ID: 2020-06-15-9-2
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-06-17
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Placeholder Value
Date of test: 06/15/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: no data g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data %
Moisture Content: no data %
Temperature Compensation Factor: no data
Test Temperature: no data F
Corrected Asphalt Binder Content: 5.20 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/17/2020 ✔