Test 2020-05-29-29-5 (AASHTO T324-14) Summary

Project Information
Project IdentifiersProject ID: 214731
DEA: 051M0004
EFIS: 0519000047
DIST-CO-RTE-PM05-SLO-101-16.5/R21.5
Work DescriptionCOLD PLANE AND RHMA-GAP GRADED OVERLAY ON EXISTING ROADWAY.
Location DescriptionSAN LUIS OBISPO COUNTY IN AND NEAR PISMO BEACH FROM 0.1 MILE SOUTH OF PRICE CANYON ROAD TO SAN LUIS CREEK BRIDGE
Sample Information
Sample Taken Date5/29/2020 Sample Unique Key29
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/10/2020
Sample typeVerification A brief description of the sampleBoxes of RHMA-G
The quantity of what the sample constitutesOne JMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byNoah Last name of sampler or witnessed byHunt
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility namePapich Paso Robles Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot numberUnknown
Sublot numberUnknown JMF Verification ID JMF3513-2020-140
Test Details
DIME Sample ID: 2020-05-29-29
DIME Test ID: 2020-05-29-29-5
Testing Lab: CT D05 - Field Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2020-06-16
Test Results

Input Type: Measured
Tester's full name: E. Atkins
Date of test: 06/15/2020
HMA Production: Field Plant Produced
Specified number of passes at 12.7 mm: 15000
Specified number of passes at inflection point: 25000
Type and Amount of Anti-Stripping Additive: 1.0% Dry Lime
Compaction Method: SGC Cylindrical Specimen
Test Temperature: 122 F
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 15000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 15000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 5.41 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 8.58 mm
Stripping Inflection Point (Wheel A): >20000
Stripping Inflection Point (Wheel B): 10122
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average:15000
Impression at specified number of passes average:7 mm
General comments (publicly viewable) (Max 1000 characters): Inflection point is report only with CPD 19-8 CCO for RHMA-G HWT.

Test was verified on 06/16/2020