Summary for Test 2019-03-20-2-2

Test performed: ASTM C109-16a

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/20/2019 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/20/2019
Sample typeAnnual Source Testing A brief description of the sampleType I/II
The quantity of what the sample constitutes1 Bucket From where was the sample collectedSource
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of sampler Telephone number of sampler
Laboratory sample identificationCM195913 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGCC Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeCementitious BrandGCC of America
MillPueblo Colorado Type of Cementitious MaterialType II Cement

Test Details

DIME Sample ID: 2019-03-20-2
DIME Test ID: 2019-03-20-2-2
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Test Release Date: 2021-01-08

Test Results


Will control cubes be used per ASTM C311?: no
Input Type: Calculated
Tester's full name: Spencer Adams
Date of test: 05/24/2019
Age of specimen: 3 days
The amount of flow : no data
The amount of water used : 48.5 %
Compressive strength of 1st specimen : 3777 psi
Compressive strength of 2nd specimen: 3711 psi
Compressive strength of 3rd specimen : 3749 psi
Average Compressive strength (to nearest 10 psi): 3750 psi
General comments (publicly viewable) (Max 1000 characters): 3 day test

Test was verified on 1/8/2021