Test 2020-05-12-22-5 (AASHTO T96-02r10) Summary

Project Information
Project IdentifiersProject ID: 214868
DEA: 074P4204
EFIS: 0717000231
DIST-CO-RTE-PM07---
Work DescriptionNot set
Location DescriptionNot set
Sample Information
Sample Taken Date5/12/2020 Sample Unique Key22
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/3/2020
Sample typeVerification A brief description of the sample3/8 WMA-A-SP R15 Aggregates and RAP
The quantity of what the sample constitutesJMF 8 Bags From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Sun Valley Last name of sampler or witnessed byQC
Title of sampler Laboratory sample identification0289A-20
The fabricator/manufacturer/facility nameVulcan Sun Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-19-0017, 91-19-0019, 91-19-0021
The fabricator's/manufacturer's product name for the sample3/8 WMA-A-SP R15 The fabricator/manufacturer designation for the sampleUnknown
The plant number420816 SVA LTR A detailed description of where the material sample was collectedBelt Cut at Vulcan Sun Valley Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown JMF Verification ID
Test Details
DIME Sample ID: 2020-05-12-22
DIME Test ID: 2020-05-12-22-5
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2020-06-11
Test Results

Input Type: Measured
Tester's full name: Michael Magana
Date of test: 06/11/2020
Grading designation: C
Mass of sample (before test): 5000 grams
Mass of sample on No.12 sieve (after 100 revolutions): 4597 grams
Mass of sample on No.12 sieve (after 500 revolutions): 3259 grams
Percent loss after 100 revolutions:8 %
Percent loss after 500 revolutions:35 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 06/11/2020