Summary for Test 2020-06-05-20-2

Test performed: ASTM D412-06a-re13

Project Information

Project IdentifiersProject ID: 214552
DEA: 044Q1104
EFIS: 0419000347
DIST-CO-RTE-PM04-SM-84-11.7, 11.70
Award Date05/13/2019
Closeout Date12/16/2021
Work DescriptionConstruct Secant Pile Wall
Location DescriptionNear La Honda, at 3.4 miles east of Pescadero Road
QA Service Level1 (Verified on 11/21/2019)

Sample Information

Sample Taken Date06/05/2020 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/09/2020
Sample typeQuality Assurance A brief description of the sampleBearing Pad
The quantity of what the sample constitutes34 From where was the sample collectedManufacturer
First name of sampler or witnessed byBryan Last name of sampler or witnessed byNagid
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGRT Transportation Laboratory (TL) NumberC668877
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM1 - Elastomeric Bearing Pad Mfg. Lot Number(s)BP057365C
Material/Compound/Elastomer IDNA Samples Representing1
Description (size)1" x 8" x 12" CommentsUnknown
Description (Number of Shims)NA Type of Bearing PadPlain
Description (Thickness of Shims)NA Manufacturer(s)GRT
Batch NumberUnknown

Test Details

DIME Sample ID: 2020-06-05-20
DIME Test ID: 2020-06-05-20-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Test Release Date: 2020-06-11

Test Results


Number of specimens tested: 3
Unit of the Ultimate Tensile Values: lbf per sqr in
Input Type: Calculated
Tester's full name: bewing
Date of test: 06/11/2020
UTM: 2kip
Humidity: 50.00 %
Temperature: 72 F
Sample 1 Median Thickness: 0.083
Sample 1 Thickness all Within 0.003 inch?: Yes
Sample 1 Ultimate Tensile: 2491.47 lbf/in^2
Sample 1 Elongation (350% Min): Pass
Sample 2 Median Thickness: 0.082
Sample 2 Thickness all Within 0.003 inch?: Yes
Sample 2 Ultimate Tensile: 2442.84 lbf/in^2
Sample 2 Elongation (350% Min): Pass
Sample 3 Median Thickness: 0.081
Sample 3 Thickness all Within 0.003 inch?: Yes
Sample 3 Ultimate Tensile: 2426.28 lbf/in^2
Sample 3 Elongation (350% Min): Pass
Median of the Ultimate Tensile Values: 2442.8 lbf/in^2
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for Sample 1

Source: Bluehill Data Point File
Test graph for Sample 3

Source: Bluehill Data Point File
Test graph for Sample 2

Test was verified on 6/11/2020