Test 2020-02-12-43-1 (CTM 202-November 2011) Summary

Project Information
Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
Sample Information
Sample Taken Date2/12/2020 Sample Unique Key43
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing2/13/2020
Sample typeAggregate Prequalification Program A brief description of the sample3/8" Pea Gravel
The quantity of what the sample constitutes4 Bags From where was the sample collectedManufacturer
First name of sampler or witnessed byRene Last name of sampler or witnessed byMorquecho
Title of samplerQC Technician Laboratory sample identification20-APPC-0063
The fabricator/manufacturer/facility nameCEMEX - Rockfield Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-10-0014::ROCKFIELD PLANT
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown HMA Design ID
Test Details
DIME Sample ID: 2020-02-12-43
DIME Test ID: 2020-02-12-43-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2020-06-10
Test Results

What size aggregate is being tested?: 0.375 in x No. 8 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Individual Mass Retained
Input Type: Measured
Tester's full name: Bang Nguyen / Ryan Kester
Date of test: 05/22/2020
Individual mass retained on the 1/2 in. sieve: 4.2 grams
Individual mass retained on the 3/8 in. sieve: 25.1 grams
Individual mass retained on the #4 sieve: 1260.7 grams
Individual mass retained on the #8 sieve: 96 grams
Individual mass retained on the pan: 36.3 grams
Total mass of sample: 1422 grams
Cumulative percent passing the 1/2 in. sieve:100 %
Cumulative percent passing the 3/8 in. sieve:98 %
Cumulative percent passing the #4 sieve:9 %
Cumulative percent passing the #8 sieve:3 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 06/10/2020