Test 2020-06-02-5-6 (AASHTO T176-08) Summary

Project Information
Project IdentifiersProject ID: 213808
DEA: 080N6704
EFIS: 0800000536
DIST-CO-RTE-PM08-RIV-74-28.1/37.4
Work DescriptionCONSTRUCT RAISED MEDIAN AND LEFT TURN LANES.
Location DescriptionRIVERSIDE COUNTY NEAR HEMET FROM 0.6 MILE EAST OF ROUTE 215 TO 0.4 MILE WEST OF ACACIA AVENUE.
Sample Information
Sample Taken Date6/2/2020 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/3/2020
Sample typeVerification A brief description of the sample3/4 HMA-A-SP R24 Aggregates and RAP
The quantity of what the sample constitutesPSUE 9 Bags From where was the sample collectedManufacturer
First name of sampler or witnessed byCalifornia Commercial Asphalt Lake Elsinore Last name of sampler or witnessed byQC
Title of sampler Laboratory sample identification0293A-20
The fabricator/manufacturer/facility nameCalifornia Commecial Asphalt Lake Elsinore Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-33-0098, 91-33-0011
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R24 The fabricator/manufacturer designation for the sampleUnknown
The plant number53417315 A detailed description of where the material sample was collectedBelt Cut at California Commercial Asphalt Lake Elsinore Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown JMF Verification ID
Test Details
DIME Sample ID: 2020-06-02-5
DIME Test ID: 2020-06-02-5-6
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2020-06-10
Test Results

How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Danilo Ferrer
Date of test: 06/08/2020
Clay Level (Test 1): 4.6
Sand Level (Test 1): 3
Clay Level (Test 2): 5.3
Sand Level (Test 2): 3.4
Clay Level (Test 3): 5.5
Sand Level (Test 3): 3.8
Sand Equivalent (Test 1): 66
Sand Equivalent (Test 2): 65
Sand Equivalent (Test 3): 70
Sand Equivalent:67
General comments (publicly viewable) (Max 250 characters):

Test was verified on 06/10/2020