Summary for Test 2020-05-13-5-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 214176
DEA: 033F0904
EFIS: 0312000056
DIST-CO-RTE-PM03-SAC,SJ-5,160-Var
Award Date10/10/2019
Closeout Date10/27/2022
Work DescriptionREPLACE STRUCTURAL CONCRETE BRIDGES, PLACE CIDH & CISS CONCRETE PILES.
Location DescriptionSACRAMENTO COUNTY AT NORTH SACRAMENTO UNDERCROSSING AND SACRAMENTO RIVER BRIDGE AND IN SAN JOAQUIN COUNTY AT MOKELUMNE RIVER BRIDGE
QA Service Level1 (Verified on 05/29/2019)

Sample Information

Sample Taken Date05/13/2020 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/14/2020
Sample typeQuality Assurance A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes2 cylinders From where was the sample collectedJob Site
First name of sampler or witnessed byJoshua Last name of sampler or witnessed byMor
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameJobsite Transportation Laboratory (TL) Number173238
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number1615776
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collected00000000000000000
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedJobsite Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2020-05-13-5
DIME Test ID: 2020-05-13-5-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2020-06-10

Test Results


Unit system used?: US Units
Number of specimens: 5
Test performed: With no density determined
Input Type: Measured
Tester's full name: PM
Date of test: 06/10/2020
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.97 in
Average diameter of cylinder 2: 5.98 in
Average diameter of cylinder 3: 5.99 in
Average diameter of cylinder 4: 5.98 in
Average diameter of cylinder 5: 5.98 in
Maximum load on cylinder 1: 226851 lbf
Maximum load on cylinder 2: 224591 lbf
Maximum load on cylinder 3: 214239 lbf
Maximum load on cylinder 4: 230390 lbf
Maximum load on cylinder 5: 233376 lbf
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 4
Type of fracture pattern of cylinder 3: 4
Type of fracture pattern of cylinder 4: 4
Type of fracture pattern of cylinder 5: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Correction factor for cylinder 4: 1
Correction factor for cylinder 5: 1
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 27.99 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Cross sectional area of cylinder 3: 28.18 in^2
Cross sectional area of cylinder 4: 28.09 in^2
Cross sectional area of cylinder 5: 28.09 in^2
Compressive strength of cylinder 1: 8104.0 psi
Compressive strength of cylinder 2: 7996.0 psi
Compressive strength of cylinder 3: 7602 psi
Compressive strength of cylinder 4: 8203 psi
Compressive strength of cylinder 5: 8309 psi
Compressive strength (to nearest 10 psi): 8040 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for Cylinder Code 1 of 5

Source: Bluehill Data Point File
Test graph for Cylinder Code 2 of 5

Source: Bluehill Data Point File
Test graph for Cylinder Code 3 of 5

Source: Bluehill Data Point File
Test graph for Cylinder Code 4 of 5

Source: Bluehill Data Point File
Test graph for Cylinder Code 5 of 5

Test was verified on 6/10/2020