Summary for Test 2020-06-05-7-2

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 214015
DEA: 034H9504
EFIS: 0319000123
DIST-CO-RTE-PM03-SAC,SAC/YOL-12,160-0-0.4/26.3-26.4, Var, various
Award DateNot set
Closeout DateNot set
Work DescriptionRepair and modernize electromechanical bridge.
Location DescriptionIn Sacramento County at four bridges.
QA Service Level1 (Verified on 03/12/2019)

Sample Information

Sample Taken Date06/05/2020 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/08/2020
Sample typeQuality Assurance A brief description of the sample7/8 x 3 1/2 HDG A325 Bolts
The quantity of what the sample constitutes94 From where was the sample collectedDistributor
First name of sampler or witnessed byJoe Last name of sampler or witnessed byLanz
Title of samplerQA Telephone number of sampler7072085241
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBay Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)2980-02
Heat Number(s)10626550 Nut Mfg. Lot Number(s)31113-S-190518
Washer Mfg. Lot Number(s)0619-188 Bolt SpecificationASTM A325
Bolt Length(s)3 1/2" Nut SpecificationASTM A563
Washer SpecificationASTM F436 FinishHDG
Diameter/Size7/8" Bolt Mfg. Lot NumberL028MI
Rocap Test Requirement(s) Lubricant Requirements(s)BLUE DYE

Test Details

DIME Sample ID: 2020-06-05-7
DIME Test ID: 2020-06-05-7-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-06-10

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 06/09/2020
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
12B31113-S-19051872590Nut Prooffsaylor

General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 6/10/2020