Summary for Test 2020-06-02-4-3
Test performed: ASTM A970-15e1Project Information
Project Identifiers | Project ID: 213682 DEA: 11430184 EFIS: 1117000215 |
---|---|
DIST-CO-RTE-PM | 11-SD-805-8.4/8.8 |
Award Date | 12/13/2018 |
Closeout Date | 09/14/2023 |
Work Description | Bridge widening, HMA, barrier, drainage, RCP, and landscape work near Sweetwater River Bridge in Chula Vista. Widening of Sweetwater River Bridge in Chula Vista on 805. |
Location Description | Near Sweetwater River Bridge in Chula Vista on 805. |
QA Service Level | 1 (Verified on 06/01/2020) |
Sample Information
Sample Taken Date | 06/02/2020 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 06/04/2020 |
Sample type | Quality Assurance | A brief description of the sample | ASTM A706 GR 60 Headed Bar |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Arthur | Last name of sampler or witnessed by | Peterson |
Title of sampler | QA Inspector | Telephone number of sampler | 707-342-8602 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Pacific Steel Group | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L110-121-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | 1202017924 | Head Manufacturer Lot Number(s) | Lot no 1 |
Rebar Size | #9 | Headed Bar Model Name | HRC 555 |
Size of Head | Reduced Size - 4x | Head Connection Type | Forged |
Head Shape | Circular | Rebar Manufacturer | Nucor |
Head Manufacturer | Nucor | Head Fabricator | Pacific Steel Group |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2020-06-02-4
DIME Test ID: 2020-06-02-4-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2020-06-08
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 06/08/2020
UTM: 400kip
Temperature: 72 f
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 1 | 1 | 100773 | 100773 | Ok Necking | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 6/8/2020 ✔