Summary for Test 2020-05-05-10-1
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 214175 DEA: 030H4804 EFIS: 0315000198 |
---|---|
DIST-CO-RTE-PM | 03-SAC-99-0.1/1.6,11.8/21.6 |
Award Date | 08/20/2019 |
Closeout Date | 08/11/2023 |
Work Description | COLD PLANE AC PAVEMENT AND RHMA OVERLAY. |
Location Description | SACRAMENTO COUNTY IN AND NEAR GALT FROM DRY CREEK BRIDGE TO SIMMERHORN ROAD AND IN ELK GROVE AND SACRAMENTO FROM 0.9 MILE SOUTH OF ELK GROVE BOULEVARD TO MARTIN LUTHER KING JR BOULEVARD |
QA Service Level | 1 (Verified on 05/29/2019) |
Sample Information
Sample Taken Date | 05/05/2020 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/11/2020 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 2 cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | D | Last name of sampler or witnessed by | Munoz |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Jobsite | Transportation Laboratory (TL) Number | 132751 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | Wet Pile Mix 9675 |
---|---|---|---|
The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | 00000000000000000 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | Jobsite | Where the material sample would have been placed if not sampled | Unknown |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2020-05-05-10
DIME Test ID: 2020-05-05-10-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2020-06-03
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: LMC
Date of test: 06/03/2020
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 152727 lbf
Maximum load on cylinder 2: 148136 lbf
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 29 days
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 5366.0 psi
Compressive strength of cylinder 2: 5204.0 psi
Compressive strength (to nearest 10 psi): 5290 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for Cylinder Code 1 of 2
Source: Bluehill Data Point File
Test graph for Cylinder Code 2 of 2
Test was verified on 6/3/2020 ✔