Summary for Test 2020-05-26-8-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 214245
DEA: 11404604
EFIS: 1114000049
DIST-CO-RTE-PM11-SD-56-5.6
Award Date10/21/2019
Closeout Date03/01/2022
Work DescriptionCONSTRUCT 2 LANES, STRUCTURAL CONCRETE BRIDGE.
Location DescriptionSAN DIEGO COUNTY IN SAN DIEGO AT 0.5 MILE WEST OF CAMINO DEL SUR UNDERCROSSING
QA Service Level1 (Verified on 12/23/2019)

Sample Information

Sample Taken Date05/26/2020 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/29/2020
Sample typeQuality Assurance A brief description of the sampleLenton Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byRezn Last name of sampler or witnessed byRafie
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Rebar Erico Lenton Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler Manufacturer Erico Lention Intermediate Assembler or FabricatorUnknown
Rebar Size#9 Coupler ModelEL28A2
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)L9462 Rebar Heat Number(s)9001498 4094536
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2020-05-26-8
DIME Test ID: 2020-05-26-8-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2020-05-29

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 05/29/2020
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 9/29mm0316019032690326Service Splicefsaylor

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 5/29/2020