Summary for Test 2014-09-24-3-3

Test performed: CTM 643-June 2007

Project Information

Project IdentifiersProject ID: 7427
DEA: 07215934
EFIS: 0700001833
DIST-CO-RTE-PM07-LA-5-2.4/4.0
Award Date08/14/2012
Closeout Date02/20/2020
Work DescriptionWiden and Realign Freeway and Construct Ped OC, OC and UC Structures.
Location DescriptionLOS ANGELES COUNTY IN SANTA FE SPRINGS AND NORWALK FROM 0.1 MILE NORTH OF CARMENITA ROAD OVERCROSSING TO 0.1 MILE NORTH OF SILVERBOW AVENUE PEDESTRIAN OVERCROSSING
QA Service Level1 (Verified on 11/26/2012)

Sample Information

Sample Taken Date09/24/2014 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/24/2014
Sample typeAcceptance A brief description of the sampleSoil for Structural Backfill
The quantity of what the sample constitutes2 Bags From where was the sample collectedSource
First name of sampler or witnessed byLance Last name of sampler or witnessed byMiller
Title of samplerSoil Tester Telephone number of samplerUnknown
Laboratory sample identification4267B Linked DIME Sample ID0
The fabricator/manufacturer/facility nameStockpile at Bloomfield UC Abut 1 Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedStockpile at Bloomfield UC Abut 1
Where the material sample would have been placed if not sampledUnknown

Test Details

DIME Sample ID: 2014-09-24-3
DIME Test ID: 2014-09-24-3-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2015-02-20

Test Results


The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: Vincent Onoh
Date of test: 10/03/2014
Soil sample resistance (lab measure 1): 3100 Ohms
Soil sample resistance (lab measure 2): 2100 Ohms
Soil sample resistance (lab measure 3): 2150 Ohms
Soil sample resistance (lab measure 4): no data Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 2100 Ohms
Soil sample temperature: 20 C
Soil box constant: 1
pH of soil: 8.39
Minimum soil resistance corrected to 15.5: 2336 Ohms
Minimum soil resistivity at 15.5: 2336 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/20/2015