Summary for Test 2020-05-06-16-5

Test performed: AASHTO T324-14

Project Information

Project IdentifiersProject ID: 214520
DEA: 051H9804
EFIS: 0517000043
DIST-CO-RTE-PM05-SB-101-78.4/79.0
Award Date01/08/2020
Closeout Date09/25/2020
Work DescriptionROADWAY EXCAVATION, PLACE AGGREGATE BASE, HMA AND RHMA-G.
Location DescriptionSANTA BARBARA COUNTY NEAR SANTA MARIA FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF SOLOMON SUMMIT UNDERCROSSING
QA Service Level1 (Verified on 02/20/2020)

Sample Information

Sample Taken Date05/06/2020 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/13/2020
Sample typeVerification A brief description of the sampleBoxes of RHMA-G
The quantity of what the sample constitutesOne JMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byCal Last name of sampler or witnessed byPortland
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCalPortland Garey Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot numberUnknown
Sublot numberUnknown HMA Mix NumberNot set

Test Details

DIME Sample ID: 2020-05-06-16
DIME Test ID: 2020-05-06-16-5
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2020-05-19

Test Results


Input Type: Calculated
Tester's full name: D. Ramirez
Date of test: 05/18/2020
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: no data
Impression at specified number of passes average: no data
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 15000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 15000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 3.05 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 3.05 mm
Stripping Inflection Point (Wheel A): >16600
Stripping Inflection Point (Wheel B): >16600
General comments (publicly viewable) (Max 1000 characters): CPD 19-8 CCO looks at average rut depth at 15000 passes for PG 64-16, and inflection point is report only.

Test was verified on 5/19/2020