Summary for Test 2020-04-16-20-2

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 214159
DEA: 081J4104
EFIS: 0818000040
DIST-CO-RTE-PM08-SBD-71-R4.7
Award Date06/18/2019
Closeout Date08/09/2021
Work DescriptionWIDEN RAMP & RIGHT TURN LANE WITH HMA AND MODIFY ELECTRICAL SYSTEM.
Location DescriptionSAN BERNARDINO COUNTY IN CHINO HILLS AT SOQUEL CANYON PARKWAY SOUTHBOUND EXIT RAMP
QA Service Level1 (Verified on 12/02/2019)

Sample Information

Sample Taken Date04/16/2020 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/17/2020
Sample typeQuality Assurance A brief description of the sample3/4" HMA Type A
The quantity of what the sample constitutes2 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byIdris Last name of sampler or witnessed byNajjar
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA- Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0005::ALL AMERICAN ASPHALT
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedHMA Plant Cold Feed Conveyor
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-04-16-20
DIME Test ID: 2020-04-16-20-2
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-05-14

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: M. Sarder
Date of test: 04/17/2020
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 96 %
Cumulative percent passing the 1/2 in. sieve: 78 %
Cumulative percent passing the 3/8 in. sieve: 62 %
Cumulative percent passing the #4 sieve: 41 %
Cumulative percent passing the #8 sieve: 30 %
Cumulative percent passing the #16 sieve: 22 %
Cumulative percent passing the #30 sieve: 16 %
Cumulative percent passing the #50 sieve: 11 %
Cumulative percent passing the #100 sieve: 8 %
Cumulative percent passing the #200 sieve: 5.5 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/14/2020