Test 2020-04-14-34-1 (CTM 202-November 2011) Summary
Project Information
Project Identifiers | Project ID: 211260 DEA: 072159U4 EFIS: 0715000160 | ||
---|---|---|---|
DIST-CO-RTE-PM | 07-LA,ORA-5-0.0/1.5, 44.3/44.4 | ||
Work Description | CONSTRUCT HOV LANES AND MIX FLOW LANES. | ||
Location Description | LOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK |
Sample Information
Sample Taken Date | 4/14/2020 | Sample Unique Key | 34 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 4/15/2020 |
Sample type | Acceptance | A brief description of the sample | 1" PCC AGG FOR ACCEPTANCE |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | HONESTO | Last name of sampler or witnessed by | CASTILLO |
Title of sampler | MREA | Laboratory sample identification | 9750 |
The fabricator/manufacturer/facility name | NATIONAL READY MIX ARTESIA, SOURCE VULCAN CORONA | Transportation Laboratory (TL) Number | 965751 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA or name of Pit) | 91-33-0027 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | NA |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | HMA Design ID |
Test Details
DIME Sample ID: 2020-04-14-34
DIME Test ID: 2020-04-14-34-1
Testing Lab: CT - Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2020-05-13
Test Results
What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Input Type: Calculated
Tester's full name: Matthew Clayton
Date of test: 04/23/2020
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:93 %
Cumulative percent passing the 3/4 in. sieve:71 %
Cumulative percent passing the 1/2 in. sieve:22 %
Cumulative percent passing the 3/8 in. sieve:5 %
Cumulative percent passing the #4 sieve:1 %
Cumulative percent passing the #8 sieve:1 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 05/13/2020 ✔