Summary for Test 2020-04-14-31-2

Test performed: CTM 227-December 2014

Project Information

Project IdentifiersProject ID: 212600
DEA: 07293704
EFIS: 0713000239
DIST-CO-RTE-PM07-LA-110,405-8.0/9.0,12.2/13.2
Award Date02/27/2018
Closeout Date08/03/2023
Work DescriptionWIDEN SHOULDER AND AUXILIARY LANE OF CONNECTOR.
Location DescriptionLOS ANGELES COUNTY IN AND NEAR CARSON ON ROUTE 110 FROM 0.2 MILE NORTH OF TORRANCE BOULEVARD UNDERCROSSING TO 190TH STREET UNDERCROSSING AND ON ROUTE 405 FROM MAIN STREET UNDERCROSSING TO 190TH STREET UNDERCROSSING
QA Service Level1 (Verified on 04/03/2018)

Sample Information

Sample Taken Date04/14/2020 Sample Unique Key31
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/15/2020
Sample typeAcceptance A brief description of the sample1" Aggregate for Acceptance
The quantity of what the sample constitutes1 bag, 450CY From where was the sample collectedManufacturer
First name of sampler or witnessed byTuan Last name of sampler or witnessed byNguyen
Title of samplerMREA Telephone number of sampler
Laboratory sample identification9753 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCemex Teady Mix Compton Transportation Laboratory (TL) Numberna
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)00-00-0000
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedna
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1 inch
The concrete mix design number1605762 Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-04-14-31
DIME Test ID: 2020-04-14-31-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2020-05-11

Test Results


Describe the gradation of the aggregate or the test method:: All aggregate is the same size
Input Type: Calculated
Tester's full name: Matthew Clayton
Date of test: 04/22/2020
Cleanness value (single primary size): 71
General comments (publicly viewable) (Max 1000 characters): Out of Spec

Test was verified on 5/11/2020