Test 2020-04-14-23-2 (CTM 217-June 2011) Summary

Project Information
Project IdentifiersProject ID: 211260
DEA: 072159U4
EFIS: 0715000160
DIST-CO-RTE-PM07-LA,ORA-5-0.0/1.5, 44.3/44.4
Work DescriptionCONSTRUCT HOV LANES AND MIX FLOW LANES.
Location DescriptionLOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
Sample Information
Sample Taken Date4/14/2020 Sample Unique Key23
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/15/2020
Sample typeAcceptance A brief description of the sampleWCS for PCC Acceptance
The quantity of what the sample constitutes3 containers From where was the sample collectedManufacturer
First name of sampler or witnessed byZaid Last name of sampler or witnessed byAbdelkhalq
Title of samplerTET Laboratory sample identification9749
The fabricator/manufacturer/facility nameHanson Irwindale Transportation Laboratory (TL) NumberTNT1
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-19-0025
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedUnknown
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Sizefine
The concrete mix design numberHRC14058 Lot numberUnknown
Sublot numberUnknown HMA Design ID
Test Details
DIME Sample ID: 2020-04-14-23
DIME Test ID: 2020-04-14-23-2
Testing Lab: CT - Southern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2020-04-29
Test Results

Number of tests: 2
Input Type: Calculated
Tester's full name: Larry Diaz
Date of test: 04/24/2020
Temperature correction:0
Temperature of solution:72
Clay reading (test 1):4.8
Sand reading (test 1):3.8
Clay reading (test 2):5
Sand reading (test 2):4
Sand equivalent (test 1):80
Sand equivalent (test 2):80
Sand equivalent before temperature correction:80
Sand equivalent after temperature correction:80
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 04/29/2020