Summary for Test 2020-04-03-9-4

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 213580
DEA: 051C2604
EFIS: 0512000108
DIST-CO-RTE-PM05-SBT-25-25.9/26.3
Award Date11/09/2018
Closeout Date05/29/2020
Work DescriptionCURVE REALIGNMENT, RETAINING WALL, CULVERT EXTENSION.
Location DescriptionSAN BENITO COUNTY ABOUT 23 MILES SOUTH OF HOLLISTER FROM 0.06 MILE SOUTH OF LA GLORIA ROAD TO 0.20 MILE SOUTH OF ENTRANCE TO CALIFORNIA DEPARTMENT OF FORESTRY COMPOUND
QA Service Level1 (Verified on 09/06/2019)

Sample Information

Sample Taken Date04/03/2020 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/20/2020
Sample typeVerification A brief description of the samplebags of aggregate
The quantity of what the sample constitutesOne JMF verification From where was the sample collectedManufacturer
First name of sampler or witnessed byAnthony Last name of sampler or witnessed byRomiza
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGraniterock Aromas Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-35-0012::A.R. WILSON QUARRY
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedAt the Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-04-03-9
DIME Test ID: 2020-04-03-9-4
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2020-04-28

Test Results


How many times will the test be run?: 3 Times
Input Type: Calculated
Tester's full name: Daniel Gingras
Date of test: 04/23/2020
Sand Equivalent (Test 1): 79
Sand Equivalent (Test 2): 80
Sand Equivalent (Test 3): 81
Sand Equivalent: 80
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/28/2020