Test 2020-04-20-6-5 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 211848
DEA: 112T2174
EFIS: 1116000131
DIST-CO-RTE-PM11-SD-5-R37.4 - R46.5
Work Description(Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave.
Location DescriptionIN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING
Sample Information
Sample Taken Date4/20/2020 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/24/2020
Sample typeQuality Assurance A brief description of the sample Resistance Butt Welded Hoops
The quantity of what the sample constitutes1380 From where was the sample collectedSource
First name of sampler or witnessed byMike Last name of sampler or witnessed byKopenski
Title of samplerQA Inspector Laboratory sample identification
The fabricator/manufacturer/facility nameCMC Rebar Etiwanda Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL149-030-20 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4094457
Hoop Manufacturer Lot Number(s)33 through 42 Material Standard CodeASTM A706
Material Grade60 Rebar Size#7
Diameter of Hoop4'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded
Test Details
DIME Sample ID: 2020-04-20-6
DIME Test ID: 2020-04-20-6-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2020-04-24
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 04/24/2020
UTM:400kip
Temperature:72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12387/22mm0.659948.5299914Ok Neckingbewing

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 04/24/2020