Summary for Test 2020-03-25-16-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 212501
DEA: 022E4804
EFIS: 0200000586
DIST-CO-RTE-PM02-SIS-96,263-103.1/103.6,56.8/57.2
Award Date12/14/2018
Closeout Date12/01/2021
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionSISKIYOU COUNTY ABOUT 8 MILES NORTH OF YREKA ON ROUTE 96 FROM 0.5 MILE WEST TO 0.2 MILE EAST OF ROUTE 263 AND ON ROUTE 263 FROM 0.3 MILE NORTH OF SHASTA RIVER BRIDGE #02-0014 TO ROUTE 96
QA Service Level1 (Verified on 06/06/2017)

Sample Information

Sample Taken Date03/25/2020 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/25/2020
Sample typeAcceptance A brief description of the sampleStructure Backfill
The quantity of what the sample constitutes2000 cy From where was the sample collectedJob Site
First name of sampler or witnessed byChad Last name of sampler or witnessed byEnsminger
Title of sampler Telephone number of sampler
Laboratory sample identificationD78365 Linked DIME Sample ID
The fabricator/manufacturer/facility nameUnknown Transportation Laboratory (TL) Number850983
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameRetaining Wall and Abutment

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Unknown
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile at Anderson Grade Staging Area
Where the material sample would have been placed if not sampledBehind retaining wall and abutment Primary Aggregate Nominal Size1-1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-03-25-16
DIME Test ID: 2020-03-25-16-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2020-04-21

Test Results


What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Individual Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 03/27/2020
Individual Mass RetainedCumulative Percent Passing
grams
0 grams100 %
0 grams100 %
964 grams94 %
2398 grams79 %
3613 grams56 %
1526 grams46 %
1696 grams35.6 %
830 grams30 %
1549 grams21 %
140 grams15 %
87 grams12 %
56 grams9 %
43 grams8 %
37 grams6 %
28 grams5.1 %
124.5 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/21/2020