Test 2020-03-24-8-3 (ASTM F606-14) Summary

Project Information
Project IdentifiersProject ID: 214421
DEA: 01362704
EFIS: 0116000031
DIST-CO-RTE-PM01-MEN-1-62.2/R78.9
Work DescriptionHOT MIX ASPHALT OVERLAY.
Location DescriptionMENDOCINO COUNTY NEAR FORT BRAGG FROM 0.1 MILE NORTH OF PUDDING CREEK BRIDGE TO 0.6 MILE NORTH OF WAGES CREEK BRIDGE
Sample Information
Sample Taken Date3/24/2020 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/10/2020
Sample typeQuality Assurance A brief description of the sampleASTM A193 B7 Stud
The quantity of what the sample constitutes200 pieces From where was the sample collectedFabricator
First name of sampler or witnessed byMahlon Last name of sampler or witnessed byLindenmuth
Title of samplerQA Inspector Laboratory sample identification
The fabricator/manufacturer/facility nameBAY STANARD MANUFACTURING Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)N/A
Heat Number(s)10599080 Nut Mfg. Lot Number(s)N/A
Washer Mfg. Lot Number(s)N/A Bolt SpecificationASTM A193 B7
Bolt Length(s)18" Nut SpecificationN/A
Washer SpecificationN/A FinishASTM A153 HDG
Diameter/Size3/4" Bolt Mfg. Lot Number2002171A-4
Rocap Test Requirement(s)NO Lubricant Requirements(s)NO
Test Details
DIME Sample ID: 2020-03-24-8
DIME Test ID: 2020-03-24-8-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2020-04-15
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 04/15/2020
UTM:400kip
Temperature:72
NumSampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
13UNC 3/4 0.3344619820513830912855042936A193 B7 Stud

General comments (publicly viewable) (Max 1000 characters): A193 B7 Stud
Test Graph
Source: Bluehill Data Point File

Test was verified on 04/15/2020