Summary for Test 2014-09-22-14-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 209263
DEA: 080F6604
EFIS: 0800000146
DIST-CO-RTE-PM08-SBD-247-1.8/9.6
Award Date04/28/2014
Closeout Date06/13/2016
Work DescriptionCONSTRUCT SHOULDERS, COLD PLANE AND HMA OVERLAY
Location DescriptionSAN BERNARDINO COUNTY IN AND NEAR YUCCA VALLEY FROM EL CORTEZ ROAD TO HANDLEY ROAD
QA Service Level1 (Verified on 04/16/2014)

Sample Information

Sample Taken Date09/22/2014 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/22/2014
Sample typeAnnual Source Testing A brief description of the sampleOne inch PCC Aggregates
The quantity of what the sample constitutes8 Bags From where was the sample collectedSource
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identification4267B Linked DIME Sample ID0
The fabricator/manufacturer/facility nameHi Grade Lucern Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)SMARA 91 36 0042
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpiles
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2014-09-22-14
DIME Test ID: 2014-09-22-14-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2014-11-19

Test Results


What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Vance Olsen
Date of test: 10/29/2014
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 95 %
Cumulative percent passing the 3/4 in. sieve: 69 %
Cumulative percent passing the 1/2 in. sieve: 29 %
Cumulative percent passing the 3/8 in. sieve: 9 %
Cumulative percent passing the #4 sieve: 3 %
Cumulative percent passing the #8 sieve: 3 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/19/2014