Summary for Test 2020-02-14-14-4
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 213733 DEA: 051C85U4 EFIS: 0518000156 |
---|---|
DIST-CO-RTE-PM | 05-SCR-1-10.2/17.5 |
Award Date | 02/19/2019 |
Closeout Date | 11/15/2021 |
Work Description | Santa Cruz 1 CAPM and Bridge Rails |
Location Description | SANTA CRUZ COUNTY IN AND NEAR SANTA CRUZ FROM NORTH APTOS UNDERPASS TO JUNCTION ROUTE 9. |
QA Service Level | 1 (Verified on 02/14/2019) |
Sample Information
Sample Taken Date | 02/14/2020 | Sample Unique Key | 14 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/04/2020 |
Sample type | Verification | A brief description of the sample | Loose Mix HMA-A |
The quantity of what the sample constitutes | One JMF | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Anthony | Last name of sampler or witnessed by | Romiza |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Granite Salinas | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-02-14-14
DIME Test ID: 2020-02-14-14-4
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-03-20
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: E. Atkins
Date of test: 03/20/2020
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 2217.4 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 2092.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.47 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 5.15 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/20/2020 ✔