Summary for Test 2014-09-23-2-1

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 209290
DEA: 044S6204
EFIS: 0414000074
DIST-CO-RTE-PM04-SON-1-34.3/34.7
Award Date04/14/2014
Closeout Date07/17/2015
Work DescriptionCONSTRUCT SOLDIER PILE TIE-BACK WALL AND WIDENING ROADWAY.
Location DescriptionSONOMA COUNTY NEAR FORT ROSS FROM 0.5 MILE NORTH OF FORT ROSS ROAD TO 0.5 MILE SOUTH OF TIMBER COVE ROAD
QA Service Level1 (Verified on 02/12/2014)

Sample Information

Sample Taken Date09/23/2014 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/29/2014
Sample typeVerification A brief description of the sampleconcrete cylinders
The quantity of what the sample constitutesUnknown From where was the sample collectedOther
First name of sampler or witnessed byKeith Last name of sampler or witnessed byLwamto
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identification059142 Linked DIME Sample ID0
The fabricator/manufacturer/facility nameUnknown Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierUnknown
Structure nameUnknown

Material Information

Material TypeConcrete The concrete mix design numberna
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collectedna
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedTruck Where the material sample would have been placed if not sampledNot set
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2014-09-23-2
DIME Test ID: 2014-09-23-2-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2014-10-21

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Larry McCrum
Date of test: 10/21/2014
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 116537 lb
Maximum load on cylinder 2: 115058 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 4107.8 psi
Compressive strength of cylinder 2: 4070.0 psi
Compressive strength (to nearest 10 psi): 4090 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/21/2014