Summary for Test 2020-03-10-13-1
Test performed: ASTM A370-15Project Information
Project Identifiers | Project ID: 212914 DEA: 031E0604 EFIS: 0312000068 |
---|---|
DIST-CO-RTE-PM | 03-YUB-70-15.5/16.5 |
Award Date | 07/31/2019 |
Closeout Date | 08/30/2023 |
Work Description | SIMMERLY SLOUGH BRIDGE REPLACEMENT BR 16-0019 WITH BR 16-0055. |
Location Description | NEAR MARYSVILLE, FROM 0.1 MILE NORTH OF BINNEY JUNCTION UNDERPASS TO 0.3 MILE NORTH OF LAURELLEN ROAD, AT SIMMERLY SLOUGH BRIDGE BR 16-0019. |
QA Service Level | 1 (Verified on 08/22/2019) |
Sample Information
Sample Taken Date | 03/10/2020 | Sample Unique Key | 13 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/16/2020 |
Sample type | Quality Assurance | A brief description of the sample | Coupon Casting |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Debbie | Last name of sampler or witnessed by | Ozuna |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | DSI Farrar | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | A290 B050 |
---|---|---|---|
Part Number (s) | 68 19 172 | Material Specification | A536 |
Grades | 80-55-06 | Metal Foundry Manufacturer (Mill) | Farrar Corporation |
Prestressing Manufacturer | DSI |
Test Details
DIME Sample ID: 2020-03-10-13
DIME Test ID: 2020-03-10-13-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2020-03-18
Test Results
Number of Samples: 4
Input Type: Calculated
Tester's full name: fsaylor
Date of test: 03/18/2020
UTM: 67kip
Temperature: 72 F
Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | A290 | 0.503 | 0.19871 | 63560 | 111562 | 8.8 | fsaylor | |
2 | A290 | 0.503 | 0.19871 | 63769 | 111899 | 8.8 | fsaylor | |
3 | B505 | 0.502 | 0.19792 | 60870 | 105903 | 10 | fsaylor | |
4 | B505 | 0.503 | 0.19871 | 61168 | 105884 | 9.4 | fsaylor |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Test was verified on 3/18/2020 ✔