Summary for Test 2019-10-18-13-5
Test performed: CTM 643-June 2007Project Information
Project Identifiers | Project ID: 214706 DEA: 120M8204 EFIS: 1214000041 |
---|---|
DIST-CO-RTE-PM | 12-ORA-1-7.9/10.5 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 1 (Verified on 12/10/2020) |
Sample Information
Sample Taken Date | 10/18/2019 | Sample Unique Key | 13 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/29/2019 |
Sample type | Preliminary | A brief description of the sample | SOIL SAMPLE OF SUBGRADE 2'-4' DEPTH |
The quantity of what the sample constitutes | 1 BAG | From where was the sample collected | Job Site |
First name of sampler or witnessed by | JOSE | Last name of sampler or witnessed by | MENDEZ |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | 8772 | Linked DIME Sample ID | 2019-10-18-13 |
The fabricator/manufacturer/facility name | NATIVE SOIL | Transportation Laboratory (TL) Number | C936702 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | MB-09 | Structure unique identifier | |
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | SR-01 PCH MB-09 |
Where the material sample would have been placed if not sampled | Unknown |
Test Details
DIME Sample ID: 2019-10-18-13
DIME Test ID: 2019-10-18-13-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2020-03-18
Test Results
The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: KIET PHAN
Date of test: 10/31/2019
Soil sample resistance (lab measure 1): 6000 Ohms
Soil sample resistance (lab measure 2): 1900 Ohms
Soil sample resistance (lab measure 3): 1100 Ohms
Soil sample resistance (lab measure 4): 1200 Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 1100 Ohms
Soil sample temperature: 21 C
Soil box constant: 1
pH of soil: 7.5
Minimum soil resistance corrected to 15.5: 1251 Ohms
Minimum soil resistivity at 15.5: 1251 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/18/2020 ✔