Test 2019-07-22-52-1 (CTM 643-June 2007) Summary

Project Information
Project IdentifiersProject ID: 214698
DEA: 120N8904
EFIS: 1214000130
DIST-CO-RTE-PM12---
Work DescriptionNot set
Location DescriptionNot set
Sample Information
Sample Taken Date7/22/2019 Sample Unique Key52
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/15/2019
Sample typePreliminary A brief description of the sampleNATIVE SOIL 0- 20' DEPTH
The quantity of what the sample constitutes1 BAG From where was the sample collectedJob Site
First name of sampler or witnessed byBALA Last name of sampler or witnessed byKRISH
Title of sampler TE CIVIL Laboratory sample identification8880
The fabricator/manufacturer/facility nameNATIVE Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormA-19-007 BULK Structure unique identifier
Structure nameRTE 133 PM 8 5 PM 9 3
Material Information
Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedRTE 133 PM 8.5 -9.3
Where the material sample would have been placed if not sampledUnknown
Test Details
DIME Sample ID: 2019-07-22-52
DIME Test ID: 2019-07-22-52-1
Testing Lab: CT - Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2020-03-13
Test Results

The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: KIET PHAN
Date of test: 12/03/2019
Soil sample resistance (lab measure 1): 8700 Ohms
Soil sample resistance (lab measure 2): 2400 Ohms
Soil sample resistance (lab measure 3): 1800 Ohms
Soil sample resistance (lab measure 4): 1900 Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 1800 Ohms
Soil sample temperature: 21.1 C
Soil box constant: 1
pH of soil: 8.32
Minimum soil resistance corrected to 15.5:2052 Ohms
Minimum soil resistivity at 15.5:2052 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 03/13/2020