Summary for Test 2019-12-16-24-2

Test performed: ASTM D2419-09

Project Information

Project IdentifiersProject ID: 211260
DEA: 072159U4
EFIS: 0715000160
DIST-CO-RTE-PM07-LA,ORA-5-0.0/1.5, 44.3/44.4
Award Date05/27/2016
Closeout Date08/01/2023
Work DescriptionCONSTRUCT HOV LANES AND MIX FLOW LANES.
Location DescriptionLOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
QA Service Level1 (Verified on 03/16/2016)

Sample Information

Sample Taken Date12/16/2019 Sample Unique Key24
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/17/2019
Sample typeAcceptance A brief description of the sampleCRUSH MISC, LEAN CONCRETE BASE
The quantity of what the sample constitutes1 Bag From where was the sample collectedSource
First name of sampler or witnessed byHONESTO Last name of sampler or witnessed byCASTILLO
Title of samplerMREA Telephone number of samplerUnknown
Laboratory sample identification9017 Linked DIME Sample ID2019-12-16-24
The fabricator/manufacturer/facility nameSECURITY PAVING PORTABLE PLANT- LA MIRADA Transportation Laboratory (TL) NumberC914419
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Unknown
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedUnknown
Where the material sample would have been placed if not sampledSB OFF RAMP Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-12-16-24
DIME Test ID: 2019-12-16-24-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D2419-09: Standard Test Method for Sand Equivalent Value of Soils and Fine Aggregate
Test Release Date: 2020-03-09

Test Results


How many times will the test be run?: 3 Times
Input Type: Calculated
Tester's full name: LARRY DIAZ
Date of test: 12/30/2019
Sand Equivalent: 47
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/9/2020