Test 2020-02-11-3-2 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 213411
DEA: 030H10U4
EFIS: 0317000246
DIST-CO-RTE-PM03-SAC-5-9.7/24.9
Work DescriptionNot set
Location DescriptionConstruction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct
Sample Information
Sample Taken Date2/11/2020 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing2/19/2020
Sample typeQuality Assurance A brief description of the sample#5 x 1'-2" Dia. Welded Hoops
The quantity of what the sample constitutes4 Samples from Lot #85 From where was the sample collectedFabricator
First name of sampler or witnessed byOsiel Last name of sampler or witnessed byRamirez Alvarez
Title of samplerQuality Assurance Inspector Laboratory sample identification
The fabricator/manufacturer/facility nameTNT Rebar Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL123-034-20 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)3500009960
Hoop Manufacturer Lot Number(s)Lot 85 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop1'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyTNT Rebar Company Coating StandardsUncoated
Weld TypeFlash Welded
Test Details
DIME Sample ID: 2020-02-11-3
DIME Test ID: 2020-02-11-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2020-02-20
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 02/20/2020
UTM:400kip
Temperature:72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12855/16mm0.3130354.2997917Ok Neckingbewing

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 02/20/2020