Summary for Test 2020-02-13-13-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 213763 DEA: 060Q19A4 EFIS: 0613000152 |
---|---|
DIST-CO-RTE-PM | 06-KER-58-R99.0/R100.3 |
Award Date | 02/04/2019 |
Closeout Date | 10/22/2021 |
Work Description | WIDEN SHOULDERS AND REPLACE BRIDGES |
Location Description | KERN COUNTY NEAR TEHACHAPI FROM 0.5 MILE WEST TO 0.8 MILE EAST OF SAND CANYON UNDERCROSSING |
QA Service Level | 1 (Verified on 01/09/2019) |
Sample Information
Sample Taken Date | 02/13/2020 | Sample Unique Key | 13 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/14/2020 |
Sample type | Acceptance | A brief description of the sample | 3/4 HMA-A-SP R15 |
The quantity of what the sample constitutes | 3 boxes | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | QC | Last name of sampler or witnessed by | qc |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0137A-20 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Granite Construction Arvin Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-02-13-13
DIME Test ID: 2020-02-13-13-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-02-19
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Angelito Villegas
Date of test: 02/19/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: no data g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data %
Moisture Content: no data %
Temperature Compensation Factor: no data
Test Temperature: no data F
Corrected Asphalt Binder Content: 4.71 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/19/2020 ✔