Summary for Test 2020-02-07-9-1
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 212988 DEA: 080R1604 EFIS: 0812000029 |
---|---|
DIST-CO-RTE-PM | 08-SBD-40-R50.0/R75.0 |
Award Date | 09/07/2018 |
Closeout Date | 10/11/2022 |
Work Description | REGRADE MEDIAN CROSS SLOPES |
Location Description | NEAR LUDLOW FROM 0.3 MILES EAST OF CRUCERO ROAD TO 0.4 MILE WEST OF BADGER WASH |
QA Service Level | 1 (Verified on 11/14/2018) |
Sample Information
Sample Taken Date | 02/07/2020 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/10/2020 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 2 cyliners | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Kennedy | Last name of sampler or witnessed by | Eubany |
Title of sampler | Materials Tester | Telephone number of sampler | |
Laboratory sample identification | 991-07 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Robertsons | Transportation Laboratory (TL) Number | 02072020-1 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | SC675B39 |
---|---|---|---|
The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | NA |
Concrete batch plant | Robertsons | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | 10 Cubic Yards | Where the material sample would have been placed if not sampled | DS 94 Wall |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2020-02-07-9
DIME Test ID: 2020-02-07-9-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2020-02-18
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 02/14/2020
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 131195 lb
Maximum load on cylinder 2: 136025 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 4624.4 psi
Compressive strength of cylinder 2: 4794.7 psi
Compressive strength (to nearest 10 psi): 4710 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/18/2020 ✔