Summary for Test 2020-02-11-2-3

Test performed: ASTM B499-14

Project Information

Project IdentifiersProject ID: 213489
Permit Numbers: 0817NMC1320 0819NRT0801 0819NRW0944 0819NRT0802 0819NRW0952 0819NRW1158 0819NRW1299 0820NRT0046 0820NRT0047
DIST-CO-RTE-PM08---27.05/27.55
Award Date06/01/2018
Closeout Date06/23/2021
Work DescriptionEnter onto Interstate 10 (I-10) right of way at Mountain View Avenue in the City of Redlands, to perform I-10 EB and WB off-ramps widening, install curb and gutter, ADA curb ramps, modify existing traffic signal, extend drainage box culvert, and install erosion control as per plans and specificatio
Location DescriptionI-10, EB and WB off-ramps, Loma Linda
QA Service Level1 (Verified on 08/13/2019)

Sample Information

Sample Taken Date02/11/2020 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/14/2020
Sample typeQuality Assurance A brief description of the sample3/4"-10 x 15" x 3"
The quantity of what the sample constitutes7 From where was the sample collectedManufacturer
First name of sampler or witnessed byBrian Last name of sampler or witnessed byMurray
Title of sampler Telephone number of sampler213 435 4055
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBlue Circle Corp Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL140-044-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)3093312 Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationF1554 Grade 55
Bolt Length(s)15" x 3" Nut Specificationn/a
Washer Specificationn/a FinishHot Dipped Galvanized
Diameter/Size3/4" Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2020-02-11-2
DIME Test ID: 2020-02-11-2-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2020-02-18

Test Results


Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 02/14/2020
Sample No.: 1A
Rocap Number: no data
Heat Number(s): 3093312
Mfg. Lot Number: no data
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: YELLOW PAINT
Size: .75 in
Bolt Length: 15 in
Measurement Average: 5.09 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/18/2020