Summary for Test 2020-02-11-2-1
Test performed: ASTM F606-14Project Information
Project Identifiers | Project ID: 213489 Permit Numbers: 0817NMC1320 0819NRT0801 0819NRW0944 0819NRT0802 0819NRW0952 0819NRW1158 0819NRW1299 0820NRT0046 0820NRT0047 |
---|---|
DIST-CO-RTE-PM | 08---27.05/27.55 |
Award Date | 06/01/2018 |
Closeout Date | 06/23/2021 |
Work Description | Enter onto Interstate 10 (I-10) right of way at Mountain View Avenue in the City of Redlands, to perform I-10 EB and WB off-ramps widening, install curb and gutter, ADA curb ramps, modify existing traffic signal, extend drainage box culvert, and install erosion control as per plans and specificatio |
Location Description | I-10, EB and WB off-ramps, Loma Linda |
QA Service Level | 1 (Verified on 08/13/2019) |
Sample Information
Sample Taken Date | 02/11/2020 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/14/2020 |
Sample type | Quality Assurance | A brief description of the sample | 3/4"-10 x 15" x 3" |
The quantity of what the sample constitutes | 7 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Murray |
Title of sampler | Telephone number of sampler | 213 435 4055 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Blue Circle Corp | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L140-044-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 3093312 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | F1554 Grade 55 | |
Bolt Length(s) | 15" x 3" | Nut Specification | n/a |
Washer Specification | n/a | Finish | Hot Dipped Galvanized |
Diameter/Size | 3/4" | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2020-02-11-2
DIME Test ID: 2020-02-11-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2020-02-18
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 02/14/2020
UTM: 400kip
Temperature: 72
Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
---|---|---|---|---|---|---|---|---|---|
1 | 1A | UNC 3/4 | 0.334 | 32377 | 144 | 96846 | 70720 | 23620 | F1554 Full Length Tensile |
General comments (publicly viewable) (Max 1000 characters): F1554 Full Length Tensile
Test Graph
Source: Bluehill Data Point FileTest was verified on 2/18/2020 ✔