Test 2020-02-05-5-2 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 212320
DEA: 060S5504
EFIS: 0614000220
DIST-CO-RTE-PM06-KER-99-32.40
Work DescriptionMINOR A PROGRAM: LERDO CANAL MEDIAN GAP CLOSURE
Location DescriptionNEAR BAKERSFIELD AT LERDO CANAL
Sample Information
Sample Taken Date2/5/2020 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing2/7/2020
Sample typeQuality Assurance A brief description of the sampleCouplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byEvan Last name of sampler or witnessed byStensvad
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameCMC Dayton Superior Transportation Laboratory (TL) NumberC601505
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size5 Coupler ModelD250
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)MM15104833 Rebar Heat Number(s)4093314
Rebar Size 2
Test Details
DIME Sample ID: 2020-02-05-5
DIME Test ID: 2020-02-05-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2020-02-10
Test Results

Number of Samples Tested: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 02/10/2020
UTM:400kip
Temperature:72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 5/16mm100.312740088387Service Splicebewing

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 02/10/2020