Summary for Test 2020-01-27-20-4

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 213744
DEA: 080P3904
EFIS: 0800001025
DIST-CO-RTE-PM08-SBD-18-101.5/115.9
Award Date02/01/2019
Closeout Date08/16/2023
Work DescriptionWIDEN EXISTING SHOULDER TO 8' AND CONSTRUCT SHOULDER RUMBLE STRIPS
Location DescriptionSAN BERNARDINO COUNTY FROM 0.5 MILE WEST OF ROUTE 395 TO 263 RD STREET.
QA Service Level1 (Verified on 05/30/2019)

Sample Information

Sample Taken Date01/27/2020 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/28/2020
Sample typeVerification A brief description of the sample3/4 HMA A SP R12
The quantity of what the sample constitutesPSUE 6 Bags From where was the sample collectedManufacturer
First name of sampler or witnessed byElias Last name of sampler or witnessed byHamel
Title of samplerTET Telephone number of sampler
Laboratory sample identification0117A-20 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Materials San Bernardino Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0137::CAJON CREEK
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R12 The fabricator/manufacturer designation for the sample224108 SBP SJR
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Vulcan San Bernardino
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-01-27-20
DIME Test ID: 2020-01-27-20-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2020-03-17

Test Results


Input Type: Measured
Tester's full name: Michael Magana
Date of test: 01/30/2020
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 965.9 grams
Mass of the pycnometer with water (B): 654.3 grams
Mass of the oven dried sample (before pycnometer) (A): 494.1 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 494.1 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.623
Bulk specific gravity (SSD Basis): 2.654
Apparent specific gravity: 2.707
Absorption: 1.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/17/2020