Summary for Test 2020-01-17-1-4

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 214140
DEA: 081J1104
EFIS: 0817000211
DIST-CO-RTE-PM08-RIV-10,79,86-Var
Award Date06/14/2019
Closeout Date06/23/2021
Work DescriptionREMOVE, PREPARE AND FURNISH POLYESTER CONCRETE OVERLAY.
Location DescriptionRIVERSIDE COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date01/17/2020 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/21/2020
Sample typeVerification A brief description of the sample1/2 HMA-A-SP R15
The quantity of what the sample constitutesJMF 12 Bags From where was the sample collectedManufacturer
First name of sampler or witnessed byCalifornia Commercial Asphalt Coachella Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0112A-20 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCalifornia Commercial Asphalt - Coachella Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0084::INDIO MINE
The fabricator's/manufacturer's product name for the sample1/2 HMA-A-SP R15 The fabricator/manufacturer designation for the sample41217333
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at California Commercial Asphalt Coachella Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-01-17-1
DIME Test ID: 2020-01-17-1-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2020-03-17

Test Results


Input Type: Measured
Tester's full name: Michael Magana
Date of test: 01/30/2020
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 966.4 grams
Mass of the pycnometer with water (B): 653.5 grams
Mass of the oven dried sample (before pycnometer) (A): 495.8 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 495.8 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.650
Bulk specific gravity (SSD Basis): 2.672
Apparent specific gravity: 2.711
Absorption: 0.8 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/17/2020